Grayhill Modules Contact Closure DC Input Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Grayhill Modules Contact Closure DC Input herunter. Grayhill Modules Contact Closure DC Input User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 1
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
I/O Modules
Contact Closure DC Input Modules
FEATURES
• Wire Dry Contact Sensors Directly
to Module, Eliminate External
Power Supply
• 2500 Vac Isolation
Built-In Status LED
UL, CSA, CE Mark, TÜV Certified
(TÜV not available on OpenLine
®
)
• Simplifies Field Wiring
3
4
5
+
1
2
10K
+VCC
OUTPUT
GROUND
VDC
TRANSFORMER
ISOLATION
CONTACT
DEBOUNCE
OUTPUT
DRIVER
CIRCUIT
CIRCUITRY: Negative True Logic
SPECIFICATIONS:
Specifications apply over operating
temperature range unless noted otherwise.
All Modules
Output Specifications
Output Current Range: 1-50 mA
Breakdown Voltage: 50 Vdc minimum
Off State Leakage Current: 1 µA maximum
On State Voltage Drop: 0.45 Vdc at 50 mA
maximum
General Characteristics
Isolation Voltage Field to Logic:
2500 Vac (rms) minimum
OpenLine
®
Vibration: .15mm, 10 to 50 Hz per IEC68-2-6
Mechanical Shock: 50 G's, 0.5 mS, sinsoidal
per IEC68-2-27
Storage Temperature Range:
-40°C to +100°C
Operating Temperature Range:
-40°C to +85°C
G5
Vibration: 20 G's peak or .06" double amplitude
10–2000 Hz per MIL–STD–202, Method 204,
Condition D
Mechanical Shock: 1500 G's 0.5 mS half-sine
G5, Dry Contact 70L-IDC5S 70G-IDC5S 70G-IDC24S
Specifications Units
Maximum Dry Contact Voltage Rating Vdc 25 25 25
Minimum Dry Contact Current Rating mA 5 5 5
Maximum Turn-on Time mSec 10 3.0 3.0
Maximum Turn-off Time mSec 10 3.0 3.0
Contact Resistance (Output Low) Ω≤ 1.25K 1.25K 1.25K
Contact Resistance (Output High) 25K 25K 25K
Nominal Logic Voltage (Vcc) Vdc 5 5 24
Logic Voltage Range: G5 Vdc 4.5-5.5 4.5-6 15-30
Max. Logic Supply Current mA 120
1
41 41
@ Nominal Vcc
SPECIFICATIONS: By Part Number
Type/Function
Grayhill Part Number
per MIL–STD–202, Method 213, Condition F
Storage Temperature Range:
-40°C to +125°C
Operating Temperature Range:
0°C to +60°C
Available from your local Grayhill Distributor.
For prices and discounts, contact a local Sales
Office, an authorized local Distributor or Grayhill.
OpenLine
®
TYPICAL WIRING FOR MODULE 0
0
MODULE
BASE
OR
RACK
TERMINAL
BLOCK #
B
A
I/O MODULE
PIN #
INPUT
DEVICE
INPUT
DEVICE
DC
SUPPLY
FILTER
FILTER
OPTICAL
ISOLATION
OPTICAL
ISOLATION
HYSTERESIS
HYSTERESIS
+
+
+
1
2
3
4
1
2
3
4
6
7
5
8
9
Vcc
CH. A STATUS
GND
CH. B STATUS
MODULE ID
G5
70L-IDL 70G-IDC
1
WHEN BOTH CHANNELS ARE ACTIVATED
I/O
20
Seitenansicht 0
1

Inhaltsverzeichnis

Seite 1 - OpenLine

Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.comI/O ModulesCo

Kommentare zu diesen Handbüchern

Keine Kommentare